Dimensional drawing





                                                                                                                                                                                              4285
                                                                                                                                                                                                                          1900



                                                                                                                                                                              4870                                                  1880
                                                                                                                                                                                                                  2400


                                                                                                                                                            4420                                          1070








                                                                                                                                                                                1980                                 2295




                                                                                                                                                                          1965





                                                                                                                                                                                      Technical room                  Inner wall


                                                                                                                                                                    Technical Room                     Electrical Panel
                                                                                Light Alloy Shelter 3V                           Constructed of stainless steel and
                                                                                Our  shelters  are  designed  for                aluminum  sandwich  panels  the
                                                                                mobile  installation  and  the  pro-             unit is thermally and acoustically
                                                                                tection of high level medical and                insulated. When the pod is collap-
                                                                                electronic  equipment  and  appli-               sed it meets ISO20 requirements
                                                                                cations. We have many customers                  for a shipping container.
                                                                                using these shelters as indepen-                 All  of  the  technological  systems
                                                                                dent  functional units in open spa-              are  fully  integrated  directly  into
                                                                                ces. There are several innovations
                                                                                in our shelters which have allowed               the units.
                                                                                us  to  become  Industry  leaders                All  our  containers  are  complete-
                                                                                and our reputation has led to the                ly configurable to best meet your
                                                                                wide  distribution  and  operation               needs.
                                                                                of our systems all over the world.
                                                                                Compared  to  traditional  mobile                BL3 Laboratory                                                        Tent coupling system
                                                                                units such as tents or prefabrica-
                                                                                tions we provide:

                                                                                - Rapid assembly: 15 minutes

                                                                                - Higher mechanical performance
                                                                                (stackable up to 4 pieces)

                                                                                -Greater mobility forks lift and ISO
                                                                                CORNERS


                                                                                -Longer service life anti-corrosion
                                                                                painted system

                                                                                     High Mobility                              High Mobility
     2                                                                                                                                                                                                                                    3
   1   2   3   4   5   6   7