6.73 m
33 - MEDICAL GAS SYSTEM
32 - RX PORTABLE
31 - OPERATOR STOOL
30 - TWO SIDE BASIN TROLLEY
29 - CLOSET
28 - X-RAY FILM ILLUMINATOR
27 - DEFIBRILLATOR
26 - MULTIPURPOSE TROLLEY
25 - ELECTROSURGICAL UNIT
24 - SURGICAL SUCTION UNIT, MOVABLE
23 - MODULAR MONITOR
22 - ANAESTHESIA MACHINE
21 - RECEIVING BASIN
20 - MAYO TABLE
19 - TROLLEY FOR INSTRUMENTS
/MEDICATIONS
18 - SURGICAL LIGHT
17 - OPERATING TABLE
4.35 m 4.55 m 16 - UPS
15 - FIRST AID KIT
14 - WATER PUMP
13 - HYDRAULIC CONNECTION PANEL (OUT)
12 - HYDRAULIC CONNECTION PANEL (IN)
11 - ELECTRICAL CONNECTION PANEL
10 - ELECTRICAL BOARD
9 - TOOL BOX
8 - FIRE EXTINGUISHER
7 - EMERGENCY LIGHT
6 - GROUNDING SYSTEM
5 - ISOLATION TRANSFORMER
4 - KIT ACCESSORIES
FOR STERILE ENVIROMENT
3 - ACU
2 - KIT MECHANICAL LIFTING SYSTEM
1 - EXPANDIBLE 3 VOLUME SHELTER
The operating theatre Electrical system
The operating theatre is an expandable shelter. Power Source and safety isolating transformer.
The unit is fabricated of stainless steel panels and insulated General Lighting Emergency lighting.
sandwich panels. Electrical outlets divided into groups, all under the equipotential
This combination allows for a securely constructed but light bonding.
weight unit. LCD panel for immediate electrical system condition verification.
The expansion system is completely manual and also allows The international electrical parts manufacturer and model are
operating in severe condition. available.
The operating room has the following technological Medical gas system
characteristics:
Sockets approved AFNOR/UNI according to the customer request.
Main features Gas Fittings-specific. Sockets for N2O (optional).
External dimensions closed cab (mm): Sockets for oxygen (oxygen generator optional external drive).
6,058 (L) x 2,348 (W) x 2,348 (H). Sockets empty.
Maximum overall dimensions open cab (mm): Sockets for compressed air at high and low pressure.
6,730 (L) x 6,699 (W) x 2,438 (H). Anaesthetic gas suction system.
Empty weight (without equipment): 4000 kg. Dual pressure reduction for each medical gas with alarms.
Working temperature: -15°C to +49°C (+55° on request) Surgical aspirator.
Air conditioning system
Structural features Inside temperature (Adjustable): 20-24°C.
Area of operating room: 27 m . Relative humidity: 40-60%. Replacement air = 15vol/h. (or more)
2
Floor connected with the walls, smooth, uniform, non-slip. ISO Class 5 (available). Efficiency air filtration: 99.97% with stan-
Load capacity 200kg/m . dard EPA filters. Laminar flow (on request) otherwise conducted
2
Technical compartment accessible from the outside in order, in tissue, micro-perforated. The above features make the air qua-
to avoid contamination for maintenance Volume: 6 m . lity in the operating room suitable for neurosurgery, cardiac sur-
3
Access door, automated on request. Size (w)x(l) 94x194 cm. gery, orthopaedic surgery and transplants.